Drive function
|
Operating instructions
|
Output current seting
|
By the SW1-SW3 three DIP switches to set the driver output current. Peak output current setting of specific, please refer to the drive panel diagram.
|
Set the number of micro-step breakdown
|
The SW5-SW8 four DIP switches to set the number of micro-step. Specific micro-step breakdown of the number of settings, refer to the drive panel diagram.(SW4,SW8 is vacant, no adjustment)
|
Automatic half current function
|
Users can set the drive SW4 half current function. "OFF" means half the quiescent current to the dynamic current, the pulse current is automatically reduced to 0.5 seconds to stop about half; "ON" said quiescent current and dynamic current is the same. SW4 should be set to a general user "OFF", the motor and the drive to reduce the heat generation, improved reliability.
|
Signal interface
|
PUL + and PUL-control pulse signal is not a dispute and the negative side;
DIR + and DIR-signal for the direction of the positive terminal and a negative terminal;
ENA + and ENA-enable signal to the positive terminal and a negative terminal.
|
Motor Interface
|
A + and A-connected motor phase winding; B + and B-phase winding is connected to the other motor. Need to reverse, you can swap one phase winding.
|
Power interface
|
DC power supply, voltage recommended 24VDC-60VDC, Power greater than 100W.
|
Indicator
|
Two lights. The power indicator is green, the drive is powered on the green light. Fault indicator is red, when an overvoltage, overcurrent fault, flashing or steady red light, when the fault is cleared off the red power on again.
|
Installation instructions
|
Drive external dimensions: 118*75*32mm, see specific Dimensions. Note that aside more than 10cm of space to facilitate cooling. It should be installed close to facilitate cooling the metal cabinet.
|