DM2280A

 
Overall and installation dimensions
 
Description
Drive function Operating instructions
Output current seting By the SW8-SW10 three DIP switches to set the driver output current. Peak output current setting of specific, please refer to the drive panel diagram.
Set the number of micro-step breakdown The SW1-SW5 five DIP switches to set the number of micro-step. Specific micro-step breakdown of the number of settings, refer to the drive panel diagram.(SW4,SW8 is vacant, no adjustment)
Single and double pulse setting SW7 set the pulse mode, set the double pulse mode ON, OFF pulse + direction mode.
Self-test function settings When SW1-SW5 are all OFF when the drive with the internal 1KHZ pulses to detect whether the motor is normal.
Automatic half current function Users can set the drive SW6 half current function. "OFF" means half the quiescent current to the dynamic current, the pulse current is automatically reduced to 0.5 seconds to stop about half; "ON" said quiescent current and dynamic current is the same. SW6 should be set to a general user "OFF", the motor and the drive to reduce the heat generation, improved reliability.
Signal interface PUL + and PUL-control pulse signal is not a dispute and the negative side; 
DIR + and DIR-signal for the direction of the positive terminal and a negative terminal; 
ENA + and ENA-enable signal to the positive terminal and a negative terminal.
Motor Interface A + and A-connected motor phase winding; B + and B-phase winding is connected to the other motor. Need to reverse, you can swap one phase winding.
Power interface DC power supply, voltage recommended 110VAC-220VAC, Power greater than 500W.
Indicator Two lights. The power indicator is green, the drive is powered on the green light. Fault indicator is red, when an overvoltage, overcurrent fault, flashing or steady red light, when the fault is cleared off the red power on again.
Installation instructions Drive external dimensions: 198*76*130mm, see specific Dimensions. Note that aside more than 10cm of space to facilitate cooling. It should be installed close to facilitate cooling the metal cabinet.
Current regulation
REF Peak SW8 SW9 SW10
3.2A 4.5A ON ON ON
3.5A 5.0A OFF ON ON
3.9A 5.5A ON OFF ON
4.2A 6.0A OFF OFF ON
4.6A 6.5A ON ON OFF
4.9A 7.0A OFF ON OFF
5.3A 7.5A ON OFF OFF
5.7A 8.0A OFF OFF OFF
Subdivision regulation
Pulse/Rev SW1 SW2 SW3 SW4 SW5
200 ON ON ON ON ON
400 ON ON ON ON OFF
500 ON ON ON OFF ON
600 ON ON ON OFF OFF
800 ON ON OFF ON ON
1000 ON ON OFF ON OFF
1200 ON ON OFF OFF ON
1600 ON ON OFF OFF OFF
2000 ON OFF ON ON ON
2400 ON OFF ON ON OFF
2500 ON OFF ON OFF ON
3000 ON OFF ON OFF OFF
3200 ON OFF OFF ON ON
3600 ON OFF OFF ON OFF
4000 ON OFF OFF OFF ON
5000 ON OFF OFF OFF OFF
6000 OFF ON ON ON ON
6400 OFF ON ON ON OFF
7200 OFF ON ON OFF ON
8000 OFF ON ON OFF OFF
10000 OFF ON OFF ON ON
12000 OFF ON OFF ON OFF
12800 OFF ON OFF OFF ON
20000 OFF ON OFF OFF OFF
24000 OFF OFF ON ON ON
30000 OFF OFF ON ON OFF
40000 OFF OFF ON OFF ON
60000 OFF OFF ON OFF OFF
TESP OFF OFF OFF OFF OFF